# Trunk explorer v0.4 — coherent assembly and attachment references

9 September 2026. User requested clarification/correction of the coloured skeleton mismatch and the next development step.

## Result

The v0.3 cream/cyan images superimposed two different source bodies. They were a diagnostic, not a completed registration. The new [interactive explorer](index.html) shows one source skeleton with that same source's trunk muscles. Its geometry retains the v0.2 source assembly; it does not fix the cross-source mismatch by deforming muscles or independently moving their receiving bones. The original comparison is explicitly labelled and preserved.

This is now an interactive browser candidate, using the existing FIT WebGL renderer unchanged: responsive drag rotation, vertical pan, wheel/button zoom, front/back/side presets, keyboard controls, five muscle layers, a skeleton view, bilateral/individual-side selection, switchable connective tissue and visible-surface labels, and click identification. The FIT College logo and existing colours are retained. No new library, service, purchase or account was added.

## Attachment work completed

An attachment-reference panel now explains rectus and lat origins/insertions and can highlight receiving structures. Rectus highlights the hip bones, xiphoid and costal cartilages 5–7. Lat highlights the humeri for the insertion reference. Whole-bone colour is explicitly identified as context, not a footprint. Side selection governs the highlighted side. Source `.or`/`.er` markers remain unused.

Local Blender probes inspected source-assigned tendon vertices in stated geometric end regions on both sides, against the expected receiving objects. All six probes found near-contact somewhere in their regions (minimum under 0.01 mm); this can also include intersection and does not establish anatomically correct footprints, full contact, fibre direction, or movement. The broad region medians differ substantially, because a region includes tissue extending away from the bone. See [the method, coordinates and results](attachment-surface-review.json). No nearest point was promoted to a student marker.

Fact references, checked 9 September 2026:
- [TeachMeAnatomy — abdominal wall](https://teachmeanatomy.info/abdomen/muscles/abdominal-wall/).
- [TeachMeAnatomy — latissimus dorsi](https://teachmeanatomy.info/encyclopaedia/l/latissimus-dorsi/).
- FIT EAP Lecture 5 slides 41, 46–47, preserved in the course shelf. Previous course/source range conflicts remain recorded; no assessment benchmark was changed.

## Preservation and validation

- Local Blender 5.2.1 LTS opened the v0.2 clean scene with scripts disabled. No source geometry was edited.
- All 88 source structures, 669,188 triangles and 25,462 source Tendon triangles exported into 92 material-specific draw parts. Draw parts are not separate anatomical muscles. The JSON uses float32 app-axis coordinates and uint16 triangle indices. Per-structure signatures and counts are in [build-report.json](build-report.json).
- Source material identities survive the browser conversion; tendon faces retain pale tissue colour. No material boundaries were invented on the obliques or transversus, whose source assignment is incomplete.
- Browser checks covered all layers, rotation, wheel zoom, tissue visibility, side-specific target selection, context visibility, click identification and mobile overflow. [QA report](qa-v04.json) and screenshots record this pass. No page errors or failed requests were observed. Renderer submission timings are not end-to-end frame-rate measurements.
- The whole-body implementation-v10 files, source Blender files, v0.3 measurements, original course sources and previous versions were retained. The new browser view references the existing renderer rather than rebuilding it. [Attribution](ATTRIBUTION.md) accompanies the adapted model data.

## Remaining work and recommended next step

Next: inspect and refine the remaining abdominal aponeurosis boundaries/seams and map the actual rectus and lat attachment areas in the coherent source frame. Inspect the lat insertion at the humeral groove and its broad origin separately. Then integrate an accepted regional assembly into the whole-body app and test motion with those attachment constraints, preserving separation, labels and default-on fibre information.

The cross-source registration is still unresolved. v0.10 has not received the new geometry or motion. This preview has no motion or separation controls; those working tools remain in v0.10. Surface ridges are retained but are not verified fibre trajectories. Exact Origin / Insertion / Both footprints remain planned and disabled in the attachment register, before broad 4K finishing. Continue the existing systems roadmap after the anatomical corrections; Skills Locker remains Mitch's later integration.
